Tiitan Three-phase PV Inverter Apollo_8000/10K/12K/15K/17K/20K/25K/30k-T1
- The DC capacitance ratio can reach as high as 1.5 times, which is perfectly suitable for high currentand double-sided solar panels.
- DC arcing detection function can be selected to eliminate potential fire hazards.
- The adaptive control algorithm adopted ensures the product fit for unstable grid.
- Flexible monitoring modes support RS485, Wi-Fi and GPRS.
- The product has IP66 degrees of protection and C5 anti-corrosion.
- The product supports output of 1.1 times overload. This effectively increases power generation.
- Description
Description
Technical parameters: | Apollo 8000-T1
| Apollo 10K-T1
| Apollo 12K-T1
| Apollo 15K-T1
| Apollo 17K-T1
| Apollo 20K-T1
| Apollo 25K-T1
| Apollo 30K-T1
|
Input parameters (DC) | ||||||||
Maximum panel input power recommended (kW) | 12 | 15 | 18 | 22.5 | 25.5 | 30 | 32.5 | 39 |
Maximum DC input voltage (V) | 1100 | |||||||
Maximum input current of each MPPT (A) | 16 | 20 | 26 | 32 | ||||
Short circuit current of each MPPT (A) | 25 | 25 | 39 | 50 | ||||
Max.Power of each MPPT (kW) | 9.6 | 12 | 15.6 | 19.5 | ||||
No. of MPPT / strings | 2/1 | 2/2 | 2/2 | 2/2+3 | ||||
Start-up voltage (V) | 180 | |||||||
MPPT Voltage range (V) | 160V~1000 | |||||||
Full-load MPPT Voltage range (V) | 550~850 | |||||||
Rated input voltage (V) | 600 | |||||||
Output parameters (AC) | ||||||||
Rated output power (kW) | 8.8kW@40℃ 8kW@45℃ | 11kW@40℃ 10kW@45℃ | 13.2kW@40℃ 12kW@45℃ | 16.5kW@40℃ 15kW@45℃ | 18.7kW@40℃ 17kW@45℃ | 22kW@40℃ 20kW@45℃ | 27.5kW@40℃ 25kW@45℃ | 33kW@40℃ 30kW@45℃ |
Maximum apparent power (kVA) | 8.8 | 11 | 13.2 | 16.5 | 18.7 | 22 | 27.5 | 33 |
Max.output power (kW) | 8.8 | 11 | 13.2 | 16.5 | 18.7 | 22 | 27.5 | 33 |
Output connection type | 3W+PE or 3W+N+PE | |||||||
Rated voltage/Voltage range (V) | 380/320~480 | |||||||
Rated grid frequency | 45~55Hz / 55~ 65Hz (According to local grid standards) | |||||||
Rated output current (A) | 12.2 | 15.2 | 18.2 | 22.8 | 25.8 | 30.4 | 38.0 | 45.6 |
Maximum output current (A) | 13.4 | 16.7 | 20.1 | 25.1 | 28.4 | 33.4 | 41.8 | 50.1 |
Power Factor (settable) | > 0.99 @ full power (adjustable range: 0.8 leading ~ 0.8 lagging) | |||||||
Total Harmonic Distortion THDi (full load) | <3% (full load) | |||||||
MPPT efficiency | Efficiency 99.9% | |||||||
Maximum efficiency | 98.4% | 98.5% | 98.6% | 98.6% | ||||
Euro. efficiency | 97.8% | 98.0% | 98.1% | 98.2% | ||||
China efficencty | 97.5% | 97.8% | 98.0% | 98.0% | ||||
DC switch with Shunt release | Protection function Available | |||||||
Output short circuit protection | Available | |||||||
Power grid fault monitoring | Available | |||||||
DC reverse connection protection | Available | |||||||
String monitoring | Available | |||||||
DC lightning protection | type II | |||||||
AC lightning protection | type II | |||||||
DC insulation impedance detection | Available | |||||||
AC leakage current detection | Available | |||||||
Over-temperature protection | Available | |||||||
DC component monitoring | Available | |||||||
DC fuse | / | |||||||
Islanding detection | Available | |||||||
Smart IV diagnosis | Available | |||||||
Arc fault detection | Optional | |||||||
Bus voltage monitoring | Available | |||||||
PID repair and protection | Optional | |||||||
Low Voltage Ride Through | Available | |||||||
Arc fault detection | Option | |||||||
Remote upgrade and setup | Available | |||||||
anti-counterflow meter | Available | |||||||
Fault recorded | Available | |||||||
Nighttime SVG features | Optional | |||||||
Display mode | Display and communication LED+bluetooth+APP | |||||||
Communication mode | RS485/4G/WIFI |
General parameters | ||
Dimension (mm)(W×H×D) | 430×380×180 | |
Weight (kg) | 17 | 17 |
Operating temperature range | -30℃~+60℃ (>45°Derating use) | |
Cooling mode | Air colling without fan | Intelligent air cooling with Fan |
Maximum altitude for product operation | 4000m (>2000m Rating reduction occurs) | |
Relative Humidity | 0~100% | |
Input terminal | MC4 (Amphenol) | |
Output terminal | OT/DT terminal(Max.50mm2 cable section) | |
Degree of protection | IP66 | |
Self power consumption at night | <1W | |
Noise (dB) | <35 | <40 |
Topology | no transformer |
Certification | |
Standards | NBT32004,IEC62109,IEC61727,IEC61683,IEC62116 |
Warranty | 5 Year Product Warranty, 10 Year Performance Warranty |